wns oil hot water boiler example

Gas boiler safe operating procedures: gas-fired boilers this kitchen I believe we are not unfamiliar fishes it. But this thing is not so easy, and sometimes improper operation causing very serious consequences, so the gas boiler rules is very important. That in the end this is how the specific operation of it, if you want to know, quickly told us with a look. 1. All personnel must be familiar with the operation of the boiler performance and safety knowledge of the boiler operating certificates. This post is strictly prohibited non-operating personnel. Duty should be strictly in accordance with the operating records and do a good job shift recording, the security situation and the device should shift change operation tests, carried out. When the shift to check the boiler is intact. 2. Boilers and safety accessories should be inspected, and in the period. 3. Kai blast furnace gas furnace ready ① Check if the gas pressure is normal, not too high or too low, open the door of oil and gas supply section; ② Check whether the pump Sheung Shui, or opening the purge valve, until the Sheung Shui so far. Open the Water Supply System for each section of the door (front door section Sheung including pumps and boilers); ③ check level gauge, the water level should be in the normal position, the water level gauge, a water level required color plug in the open position, the water level to prevent false, if water can be manually Sheung; ④ check valves on the pressure pipe, must be opened, the wind deflector must all flue opening; each knob ⑤ checks the control cabinet are in their normal position; ⑥ steam boiler check valve should be in the closed state wns hot water boiler example circulating pump outlet valve should be turned off; ⑦ checking water softening equipment is operating properly, a variety of indicators to create a soft water meets national standards. Open the power ⑴; ⑵ startup burner; ⑶ purge valve on the drum, is completely out of steam, the off; ⑷ inspection hole into the boiler, and the hand hole flange valves, the leak was found to be fastened, tight as the solid leakage maintenance shutdown; ⑸ pressure rise when 0.05 ~ 0.1MPA, replenishment, sewage, water supply systems and sewage screening test device while flushing water table; ⑹ when the pressure was raised to 0.1 ~ 0.15MPA, flushing pressure gauge trap; ⑺ when the pressure was raised to 0.3MPA, "fire load / small fire" knob to "fire" to strengthen the combustion; ⑻ when the pressure was raised to 2/3 of the operating pressure, start warming air supply tube, slowly open the main steam valve, to avoid water hammer; ⑼ drain valve is completely closed out of steam; ⑽ after all the drain valve closed, slowly open the main valve to open, and then half a turn; ⑾ "burner control" knob to " Auto "; ⑿ level adjustment: adjusting the water level (to manually start and stop the pump) according to a load, low load level should be slightly higher than the normal level, high load level should be slightly lower than the normal level; ⒀ steam pressure adjustment: adjusted according to a load combustion (manual adjustment Fire / small fire) ⒁ combustion state determination, determines the amount of fuel atomization air ⒂ observation condition exhaust gas temperature, smoke, temperature control is generally between 220--250 ℃ The flame color, smoke color, while observing the chimney exhaust gas temperature , concentration, adjusted to the optimum combustion state. ⑴ Open the power; ⑵ start the circulation pump; ⑶ slow circulation pump outlet valve; ⑷ startup burner; ⑸15 min "" Load fire / small fire "bit color button is turned to" fire "" ⑹ "burner control" knob spin to "automatic." 5A normal shutdown: hot water boiler ① "fire load / small fire" knob to "small fire"; ② off the burner; ③ close the fuel supply valve; ④ ⑤ closing dampers boiler after the temperature dropped to 50 ℃ , the circulation pump outlet valve closed. ⑥ stop circulation pump

The sale of the burner type and range of applications markets burner has a range of many different types, different types of burners applied are not the same. The scope of application of the burner more extensive, can be applied to the engine and ignition stove, and it appears to people's lives has brought great convenience, it has been a lot of consumers like. Burner also known as integrated burner to oil and gas-based. Fuel is generally used in small and medium sized boilers, the fuel fan heater, baked (baked) and the small fuel tank furnace. Broadly speaking, civil stove, lighter, torch, engine burner means belong to the scope and special civil combustor burner. Flame atomizer a pre-mixed component structure, also known as combustion head. It is a mixed gas of the combustion flame jets and carriers like sample, more than a single slit type slot length of about 50mm and 100mm there are two kinds, slit width 0.5mm, the former for the nitrous oxide - acetylene flame, after by an air - acetylene flame. Generally made of stainless steel, but also of aluminum or brass. A single slit (single-slot) with three slits (three-slot) two kinds. Mike atomic fluorescence spectrometry using a burner (Mekerburner), which is shaped torch flame. Two kinds of sub-cooled and air-cooled. After washing with distilled water is often required to use, to prevent corrosion and plugging the gap.

After use throughout the winter, the Central Conservatory of Music give us feedback, six V6-99 fully meet the heating needs of the school. And boiler fuel and water requirements are not high, urban water and low-pressure natural gas combustion can operate. The most important point is that nitrogen oxide emissions are very low and very happy to recommend it to others to do the brother of boiler units. --customer feedback

Hot water boiler fuel components have whatever civilian commercial or industrial production, oil wns hot water boiler example is that we often need to use, so today small'll tell you about the structure of the relevant fuel hot water boiler. A blower: a filter and a suction port of the blower equipment, ventilation into the burner through the work-related apparatus for flame adjustment to achieve. Second, the supply pump: softened water from the main water pressure economizer into the next device, thereby removing heat emission of smoke caused by hot water boiler fuel to a water preheating effect. Third, natural gas systems: the interface includes a gas, burner, natural gas adjusting means. Fourth, the security valve: equipped with a pressure relief initiative greater than the preset value. Fifth, oil hot water boiler automatic control and other components sum of these components is tantamount to fuel hot water boiler said earlier, assuming that the output way, the boiler input indicators of poor water quality, is to keep from the furnace, need to pay close attention . On the way output, fuel hot water boiler to check the maintenance schedule, rigorous process of checking maintenance records, only rigorous work, unswerving overhaul inspection before they can improve production yields greater and greater extent, have does not appear to grasp the consequences.