air heating electric hot water boiler tank

Horizontal air heating electric hot water boiler tank Description: Horizontal hot water boiler according to boiler fuel can be divided into horizontal electric water boilers, hot water boiler fuel horizontal, horizontal gas boiler, horizontal coal-fired boiler; boiler constructed according to the design can be divided into horizontal pressure hot water boilers and pressure hot water boiler.

Our jewelry processing company in the automotive production, many processes require energy, to be honest we really a headache on the choice of the air heating electric hot water boiler tank, thanks met specializes in the research and production of fast square boiler boiler! The purchase of two Taipower hot water boiler, tangible help us save a lot of costs. --customer feedback

Gas air heating electric hot water boiler tank szs 1 emergency shutdown procedures, if necessary emergency shutdown generally, when the boiler encounters one of the following, operation should be stopped in case of emergency; (1) allow the boiler steam pressure exceeds a safe pressure, fueling is stopped strengthen water supply, measures the wind pressure continues to rise. (2) boiler severe water shortages. Water meter can not see the water level. After being called water, the water level of sight. (3) When the severe water boilers, boiler water level is higher than the highest water level is visible, but the emission level not yet seen. (4) increase in boiler water, take other measures, the water level will continue to decline. (5) water supply device is turned off, standby equipment. (6) all water level gauge or invalid. (7) All the safety valve all the failures. (8) All all-off failure drain valve. (9) causing damage to the boiler pressure element (e.g., boiler tubes, etc.), or endanger the safety of the device. (10) boiler is a serious threat to other events and safety equipment. 2, natural gas boiler operation method szs immediate emergency stop operation of the controller, the boiler is off, closing the front of the boiler gas valve to stop the gas supply. The steam boiler competent completely separated, opening the exhaust air valve or safety valve steam pressure. Due to lack of water, the boiler is not allowed into the boiler, the steam is not discharged to reduce pressure. No shortage of water, cold water can drain down alternate method, the water level remains complete accident should immediately stop the water supply, water reducing combustion (fire artificially changed into a small fire), play an open valve while opening the main steam pipe and the drain valve cylinder to prevent the steam to carry large amounts of water, water. In the shutdown process, the cooling rate of the furnace should not be too fast to avoid flue compression member and the expander is damaged suddenly cooled. 3, emergency shutdown processing method szs natural gas boiler in the case of emergency shutdown, due to the nature of the accident, the following may take a different approach: (1) rapid flame treatment emergency shutdown, the burner first station, and closing the valve flame gas supply is stopped after the cut valve, to maintain the water level is normal. (2) rapidly cooling the furnace or water if there is no water leakage during an emergency stop, the cooling time can be shortened to the boiler water and sanitation and reduce the pressure. When the boiler water temperature down to 80 degrees Celsius, boiler water can be discharged. If the boiler severe water shortages, the boiler can not cool quickly in the event of an outage. Non-water to the furnace, or explode. accident. (B) natural gas boiler shutdown SZS normal shutdown (complete shutdown, shutdown maintenance) procedures which can be used when needed repair or stop steam boiler. 1. If one of these faults, the leaders agreed, the boiler can be temporarily closed repair: bilge faucets, riveted joints leak, damaged tubes, the waterwall tubes, the heating tube, the flue gas contacts the drum, the head, off pipe insulation, water supply system, combustion system, a serious fail-safe accessories, in need of repair. 2, a temporary repair (or normal shutdown) the method of operation in order to stop the burner, for closing the valve. Boiler feed water to 2cm above the normal water level, to stop water supply, reduce the pressure. 3. Turn the main steam valve, open the traps, and steam boiler operation, reliable water separator. 4, boiler feed water close electric valve and manual valve, boiler feedwater reliable cutting. When the steam pressure drops to zero, the water can be supplied and discharged alternately, so that water is gradually cooled furnace, when the temperature drops to 50 degrees Celsius (or hand potshell touch feeling hot pan head), can be completely discharging furnace boiler water water . Before water, open the air valve on the boiler or lift safety valve. At this point, you can enter the furnace for inspection and repair. Cooling the furnace must be kept slow, non-violent cooling and damage to the boiler, the boiler can be stopped from the repair into the furnace, the cooling time is generally less than 24 hours. Close the furnace over 24 hours, shut off the gas supply valve at the regulator, and open the gas conduit pipe is responsible, in the exhaust gas pipeline.

Use small electric steam air heating electric hot water boiler tank steam boiler electric steam boiler steam boiler using a small electric steam boiler electric steam boiler manufacturer boiler Class A: Yongxing boiler - designated national, A-level qualifications, professional supplier of electric steam boilers, gas boilers, coal-fired steam boilers, biomass steam boiler. Kinds of environmental protection steam boiler. Factory Scope of supply: all regions of the country and Southeast Asia. Boiler types: electric boilers, electric steam boilers. Supply and installation of: direct factory boiler, installation, commissioning and after-sales service can directly call or message advice. What are the advantages of small electric steam boilers that? One. When the electric steam boiler leak hazard, the boiler controller automatically cut off power supply to avoid electrical shock. 2. Automatic water supply function: When the water in the boiler is lower than the safety level, the automatic stop heating the heating tube to prevent damage caused by dry combustion and ignites the indicator water; III. Typically, cable is connected between the ground and well grounded. When the boiler steam pressure exceeds a set limit pressure relief valve start and release the steam to reduce the pressure. four. Overcurrent protection: When the boiler overload (high pressure), earth leakage circuit breaker is automatically disconnected. 5. Power Protection: use of advanced electronic circuit detects over-voltage fault condition, undervoltage, reliable power failure protection. 6. The vapor pressure of the small electric steam boiler with a variety of specifications, the power of the select electric steam boiler; 7. Electric steam boiler is electric energy, no noise, no pollution, no emissions of environmental protection products. 8. A steam boiler is heated by a small electric power control, ease of installation and matching, large boiler (500Kg) of the furnace is prevented and the control electronics electronic control portion of the furnace affected. High temperatures, to ensure stable operation. 9. The boiler temperature by automatic control cabinet. Insulation and electric heating control technology, the thermal efficiency of 97%. ten. Boiler advanced electrical controller having a computer boiler reliable performance, high degree of automation, easy operation. Using the electrical components to ensure high quality of production. Life products. Small electric heating steam boiler 1. The boiler performance characteristics of the boiler furnace using steel pressure vessel, the longitudinal and circumferential weld furnace automatic welding, and X-ray detection. Small furnace and electrical integration, easy installation. 2. The JB / 2379-93 standards and technical requirements of the metal pipe heating element, a low load heating surface of the heating element. Thick stainless steel high electric wire outer tube, the inner tube is filled with the high purity magnesium oxide, electrically heated tubes and long service life. Each heating element has a flange, simple structure, high mechanical strength, safety and reliability, can be replaced. 3. Compact, scientific and rational design, advanced manufacturing technology enables the boiler space is small, easy to transport, saving the use of space. four. Intelligent automatic control technology, without duty. Flexible and can be set to manual or automatic mode. 5. Set the boiler automatic operation time period, day provided several different duty cycles, the boiler is heated in each group sharing start automatically cut off the heating cycle and into the group. Contacting all use the same frequency and time, improve the life of the device. control. Seven. Full protection, leakage protection, water protection, ground fault protection, steam overvoltage protection, overcurrent protection, power protection, the boiler automatic protection, security. Full home. 8. No noise, no pollution, high thermal efficiency. High quality and efficient boiler heat insulation materials, low heat dissipation, energy saving. 9. Boiler packaging design using well-known color plate, elegant appearance, easy to rust. Small electric steam boiler - Boiler power plant with procurement requirements.