steam pellet boiler 2 ton per hour

Fast steam pellet boiler 2 ton per hour strong technical team and perfect after-sales service to our left a deep impression, the successful completion of the boiler installation and commissioning work at a predetermined period. The company offered me two Taipower heating steam boilers, combined with the actual situation of our company, as we save a lot of fuel costs, thanks to fast boiler provides us with such high-quality products and peace of mind. --customer feedback

Industrial steam pellet boiler 2 ton per hour stoker boiler overpressure staff, treatment Water Shortage Accidents: industrial boiler stoker boiler overpressure personnel, Water Shortage Accidents treatment of industrial boiler stoker boiler overpressure personnel, processing method 1 Water Shortage Accidents, industrial boilers boiler overpressure overpressure accident is due to an accident during the actual operation of the boiler in the actual pressure value exceeds the maximum working pressure caused. Boiler overpressure accident is an accident the most common accidents. Overpressure characterization: the boiler is running, when the pressure in the boiler is too high, the air pressure will be significantly increased, exceeding the safe working pressure of the boiler, boiler safety play a proactive action; boiler overpressure alarm will issue a warning signal; steam temperature rising Wait. Common causes of boiler overpressure are: gas fault does not operate normally with gas; valve failure, equipment failure alarm; relates to a boiler because defects result buck during use, the cross-sectional area of ​​the exhaust valve is not adjusted , still use the original terms of safety valves. Processing overpressure accident. Found boiler overpressure should be reduced combustion; if the boiler safety law does not work, can take artificial exhaust, or located vent valve on the boiler open for exhaust, to adjust the pressure of the boiler; maintaining an internal boiler water level is normal, reduce oven temperature; the oven before deciding to stop or resume operation, check the cause of the boiler overpressure and damage the furnace. 2, industrial boiler water accidents occur during use of the boiler, the boiler water shortage accident was mainly due to the boiler water level below the safety level. Boiler water often leads to additional boiler superheater heating surface tubes cause deformation even wave train; mouth off or leakage; boiler wall is damaged. In the use of the boiler, the boiler water accidents can not be properly resolved, will often bring very bad consequences, causing serious damage.

The reason industrial steam pellet boiler 2 ton per hour scale formation of what are: industrial boiler scale formation causes of which are first of all, water treatment measures are not in place. Situation local industrial boiler water treatment methods are set out below: Some of the salt tank with the use of small water treatment apparatus (hereinafter referred to as the outer pot water), some of trisodium phosphate and sodium hydroxide was added to the pot (hereinafter referred to as pot- ), while some units are not taking any water treatment measures, direct operation of the boiler. The outer pot using water, some units in the design of a water treatment system, the local water quality testing is not performed, the washing apparatus and the backwash time are not set according to local water conditions, the hardness of the water supply when a large, positive and negative wash time is inadequate. Are washed lack of time, can cause water supply quality standards, and the lack of time will result in the backwash exchange properties of the resin gradually decreased until failure. In the selection of water treatment equipment, water treatment equipment selection of some units capacity is too small, does not match the rated boiler evaporation, can not meet the water supply needs. Also in the installation and operation of water treatment equipment, water pressure does not reach, it will also affect the normal operation of water treatment equipment.

Induced Draft Fan. The hot flue gases from the furnace is drawn out by the Induced draft fan. The gases passes through the various heating surfaces of the steam pellet boiler 2 ton per hour, the Electrostatic Precipitator and discharges to the atmosphere at the top of the stack. Induced Draft Fan provides the energy for this flow of flue gases. The Induced Draft Fan is normally located adjacent to the Stack.