check valve block valve gas fired steam boiler

Since our company uses WNS6-1.25-YQ split two condensing boiler, the boiler runs very stable, high degree of automation, greatly reducing the labor intensity of fireman our staff, because running very clean without any emissions, but also greatly improved our paper mill house and the surrounding environment, high operating efficiency boilers. Service is also very timely response to our technical consulting reply quickly and accurately. Especially for regular visits to thank! --customer feedback

1 type: SZS D type Horizontal firetube check valve block valve fired steam boiler

WNS oil gas fired horizontal steam boiler

20 tph oil and gas boiler for Paper mill

Paper mills consume a lot of steam because of their production needs. In order to meet the production needs, paper companies need to purchase boilers for steam production. A paper mill in Iran purchased a 20-ton szs series of fuel gas boilers produced by CBM according to production needs.

Electric check valve block valve fired steam boiler flue of accumulating a certain amount of soot how to deal with? Electric steam boiler furnace cleaning backpass long-term non-stop, accumulating a certain amount of soot or carbon black. Solution: When the temperature drops below the flue 50 ℃, check before entering the flue tail heating surface, and should completely remove the flue soot. If not burning, can be re-started ignition; if burning, should be replaced, repaired burning member; large negative pressure of the combustion chamber, so that gas will be no time to burn into the electric steam boiler tail. Solution: When the exhaust gas temperature close to the temperature of the injected steam, or less than 150 deg.] C and more stable during 1h openable inspection hole inspection, after checking element determines the source of fire, the ventilation fans before starting. When shutdown or electric steam boiler fire, air gun valve is not closed. Solution: strengthen the electric steam boiler feed water and turn on the water, open the valve or economizer recirculation tube to protect the economizer being burnt; lower start, the furnace temperature during shutdown, unburned fuel in the furnace . Solution: fire extinguishing devices immediately into steam, carbon dioxide or other fire extinguishing devices; burn improperly adjusted, with insufficient wind or with the wind unreasonable. Solution: Close the flue duct and baffle around the door opening, start sending prohibited, induced draft fan.