gas hot water boilers for domestic use

Weekly maintenance items which are mainly oil-fired boilers in order to protect the security of the oil-fired boiler conducted its weekly examination is indispensable weekly to check the project are nine. 1, low level shutdown, shutdown test to be performed, according to the control cabinet side panel button, or should be able to simulate the shutdown by the sewage water, low water levels to check .2 shutdown, the valve manual opening Test , .3 to quickly reset, the burner control system and the electric eye to be examined, electric eye photocell taken, should the inner shutdown, and .4 electric eye cleaning, or replacement of the valve packing for filling, eliminate leaking. 5, around the fastening bolt, in particular a gas piping system, if necessary, to leak .6 month to clean the oil filter, the oil passage decontamination boiler fuel, gas pipe line filter .7 every six months to maintain. verification gauge tube and cleaning table .8, maintenance level electrodes, remove, .9 with fine sandpaper, cleaning the flue, generally based on the exhaust gas temperature needs to be cleaned to determine whether, under normal circumstances, exhaust gas temperature at the outlet does not exceed the boiler, measuring flue entrance) represents a too high fouling increase, reduce boiler efficiency, it must be cleaned, especially fuel boiler, to be more frequent cleaning. on the one hand, to the economy consider, on the other hand is also out of consideration (soot on safety thermal conductivity After partially burned prone). When replacing asbestos cleaning pad to the wrong port lap method (anti-smoke Ran), graphite coating, not lubricated .4) boiler repair or inspection, to check manhole, first hole, hand hole nuts can not be loosened, to check the motor rotation (see the end from the fan, turn counterclockwise). oil-fired boiler once per year check valve. conduct a comprehensive overhaul of the boiler serviced once.

Beijing New Energy Automobile Co., Ltd. is China's first to operate independently and gain new energy automobile production qualification of new energy auto companies, mainly engaged in new energy vehicles and key parts and components research and development, production, sales and service business segments, and the layout intelligent manufacturing, energy management, smart travel, Internet +, and other strategic emerging industries. In the new energy automobile manufacturing process, and a series of paint drying processes can not do without the help of hot water boilers for domestic use. Due to the company before the device has reached less than the growing production needs, the introduction of the 2017 mid-tail electric company producing heating pressure hot water boiler (CEDR0.7--95 / 70-Ⅱ).

Gas boiler conventional model: WNS series 0.5 tons, 1 ton, 2 tons, 3 tons, 4 tons, 6 tons, 8 tons, to the adverse impact of the boiler 10 tons, 15 tons, 20 tons! Biomass boiler, gas-fired boiler, oxygen-nitrogen-argon storage tank Heguotai gas-fired boiler adopts biased tank wet-back structure, high-temperature flue gas scours the second and third round-trip smoke pipes in turn, and then flows into the atmosphere from the rear smoke chamber through the chimney. The boiler is equipped with movable front and rear smoke box cover, which makes the boiler easy to repair. The boiler has good technical performance. It adopts advanced technologies such as automatic proportional adjustment of combustion, automatic regulation of feed water, start-up and stop of program, full automatic operation, and so on. Low water level alarm and very low water level, ultra high steam pressure, boiler extinguishment and other automatic protection functions. The boiler has the characteristics of compact structure, safe and reliable, simple operation, quick installation, less pollution, low noise and high efficiency. But it is important to know that, due to the increase in air volume, the center of the flame will increase the exhaust temperature, and the heat loss of exhaust gas will increase generally. Therefore, it is proved that the thermal efficiency of boiler is affected. This will give the boiler economic belt if the integrated sewage treatment equipment operation is not.

Gas steam boiler Gas steam boiler faults and fix problems economizer heat what is the reason? Acoustic cleaners using main function is used to remove fouling the heating surface of each gas-fired boiler, has the advantage of traditional mechanical cleaning, sootblowing steam and ash ball, etc. can not be compared, in the electric power, petrochemical, and other fIELD used widely, part of the solution superheater boiler system, the new non-contact heating surface cleaning method of cleaning economizer, an air preheater and a waste heat boiler, a heat pipe heat exchanger. Gas cylinder steam boiler Branch Church of the trap in what place? Gas-fired steam boiler cylinders trap points at the bottom of the cylinder, which is a standard valve, are design specifications. Horizontal Horizontal gas steam boiler and gas steam boiler how much money each one, with a good restaurant to what kind of horizontal gas steam boiler, the price is no way to determine because the size depends on your power ! And because different manufacturers offer different quality and technology will be different. So, boiler safety accessories must be required to regularly check. Gas-fired steam boiler itself flawed: When the pressure component aging, strength weakened, or leakage, corrosion, deformation, scale and other defects, not timely maintenance in order to eliminate hidden dangers, but let boiler "sick to run," and so on. Therefore, the boiler must be regularly tested according to national requirements. Poor management, fireman officer is not responsible or low levels, lead to misuse. So fireman must obtain operating permits required. Four gas steam boiler safety accessories limit how often examined once? Four steam boiler safety accessories means that safety valve, pressure gauge, water level gauge, thermometer. General safety valve check once a year. General pressure gauge check at least once every six months. Water level should be washed once per shift. After checking with the thermometer mounted least once a year. How to change the temperature of the steam boiler the steam pressure of the gas changes.