DHL series coal-fired steam boiler

The reason gas dhl series coal-fired steam boiler flame of abnormal phenomena and processing method. Flameout for the following reasons: 1. Auxiliary trip or power interruption. 2. boiler combustion instability. 3. When the load is too low, due to the sudden drop in load, ignition energy mill will be lost or the combustion is automatically stopped. 4. mutation coal, low volatile or low calorific value. Fuel gas boiler is not only fuel but also refers to the gas boiler. Previously no such dual-fuel boiler, burner because either fuel or gas, no dual fuel burners. With the rapid development of the world energy equipment, some European countries begin production and sales of fuel gas burner, dual fuel burner and boiler combination of organic birth of a new breed of boiler - fuel gas-fired boiler. 5, the automatic combustion flame detectors or failure resulting in failure to trip mill. 6. The furnace wall or squib serious improper boiler soot-blowing operation, a large amount of steam into the combustion chamber. 7, coal pulverizing system, fuel system failure, resulting in a substantial amount of fuel reduction or interruption. A large amount of water or impurities in the fuel oil gun clogging, or atomized vapor pressure is too low. Second, the phenomenon: 1, furnace pressure was significantly higher, flameless furnace flame monitoring CRT display. Pit of fire no fire. BTG MFT alarm window alarm indicator lights. 2. The unit load is reduced, steam flow drops rapidly, and the temperature of each section of the working medium vapor pressure decrease, a sharp increase in oxygen index. Steam boiler is an energy conversion device, the energy input to the boiler fuel chemical energy, electrical energy, thermal energy and other forms of high temperature flue gas, and after converting the boiler, the steam output having a certain outside thermal energy, high-temperature hot water or an organic carrier. 3. Treatment: 1. If you refuse to run MFT protection, emergency stop should be handled according to the situation and stop the supply of fuel. 2.2. Identify the cause of stalling, and try to eliminate it. Conduct a comprehensive inspection of the boiler, and to confirm proper before the device is restarted.

The Chen Yuanshi cooperation with our company, will build on the fast side to enhance the field of basic product research and development capabilities, direct docking of the world cutting-edge technology achievements for existing products can quickly complete testing and validation, thereby enhancing our side fast boiler technology value-added products, have a stronger market competitiveness.

Some of the causes direct impact on the thermal efficiency of horizontal dhl series coal-fired steam boiler of the country are carrying out a blaze of glory roaring coal to natural gas operations, the choice of horizontal steam boiler, greatly reducing the fine dust contaminated with dust, along with toxic gases such as nitrogen oxides emissions It has also been suppressed. Thermal efficiency is a key measure of horizontal steam boiler, a good start and that is that let you look at some of the causes direct impact on the thermal efficiency of horizontal steam boiler. Through research departments, the heat loss of horizontal steam boiler is very important from two aspects: the combustion air-fuel ratio is not satisfactory and Smoke and heat loss. Smoke and heat loss reduction should be modified in the tail horizontal steam boiler soot waste heat recycling install, or choose would be more leading series condensing boilers. Combustion air-fuel ratio over the substandard Analysis: common horizontal ejector-type steam boiler burner choice, without the formation of air-fuel ratio can be flexibly adjusted. Most of the horizontal steam boiler selected non-automatic strong emission burner, leading to the root causes of unsatisfactory air-fuel ratio has the following areas: air-fuel ratio is not ideal is more important is divided into two kinds of probability: When an excess of oxygen, there will be endless excessive cold air is heat conduction, resulting in increased energy consumption horizontal steam boilers, hot horizontal steam boiler efficiency decreased; when oxygen is not standard, incomplete combustion occurs, generating heat horizontal steam boiler efficiency decreased.

Introduce some common sense about the boiler 1, the critical speed of the circulating fluid bed boiler. Gas flow rate corresponding to the minimum fluidization velocity or become known as the critical fluidization velocity. 2, the flow characteristics of circulating bed boiler? A high combustion efficiency of the fuel adaptability 2 3 4 desulfurization efficiency is low nitrogen oxide emissions high combustion intensity 5, 6 simply small cross-sectional area of ​​the furnace fuel and coal pretreatment system 7, a large load adjustment range, adjustment is easy to implement fast ash 8 utilization. 3, the partition circulating fluid bed boiler furnace and the corresponding characteristics into dense and dilute phases, a lower dense phase zone of the furnace, filled with hot materials, is a stable source of hot, heat storage is a thermal store , flow therethrough in an upper dilute phase zone of the furnace, the fuel air are required. 4, the positive balance calculation boiler efficiency, combustion of coal, boiler heat losses What? Coal particles is heated and dried: volatile combustion and precipitation: coal particles swell and rupture: re-cracking and coke burning carbon particles and wear. Heat loss 1 2 3 Chemical incomplete combustion loss of physical mechanical incomplete combustion heat of the loss heat loss 4 5 ash. 5, the charging cycle 4 Effect Effect Effect amount of the main factors affecting combustion in the boiler of a coal particle size distribution and particle 2 was 3 Effect fluidization velocity excess air factor 5 bed temperature Dense Phase 6 . 6, the basic form of the heat transfer in? In the heat transfer process, there are three basic ways of heat transfer: thermal and heat transfer, convective heat and radiant heat transfer. 7, their role in recycling and recycling processes? By the economizer feed water into the steam drum, a descending pipe into the water wall, by absorbing the heat released by the combustion of the fuel heating the water in the saturated steam passes through the heat absorbing further heat saturated steam into dry steam heating. 8, sewage, drainage pipe What? Sewer: blowdown drum door (left and right) turn on the water accident door, front door header sewage, sewage tank after the door, left the door header sewage and right door header sewage, sewage water jacket door (about) Dipleg sewage door. Drainage pipe: the low temperature superheater inlet header hydrophobic doors, front / rear desuperheater hydrophobic door header, the high-temperature superheater inlet / outlet header, the header hydrophobic dispensing door. 9, then what are pipe drum? Meter and accessories? Superheater, economizer recirculation duct, platoon expansion tube, a condenser tube, soot blower tube, economizer inlet pipe, the discharge pipe accident, centralized downcomer platoon expansion, a water level gauge, a thermometer, security door, pressure gauge, gas-water separator, header. 10, the cyclone structure and working principle? Cylindrical body, the central cylinder, a cone, a loop seal, the material returning leg, from the high temperature flue gas out of the furnace, two left and right into the two cyclones, increase after turning flue flue gas velocity in the cylinder the center of rotation of the form cylinder back down into the cone upwardly from the central cylinder wall Shuaixiang excluded smoke particles under high effort when the cone reaches the end coupled with its heavy fall below the loop seal. 11, Refeeder role? The ash from the circulation loop seal into the furnace combustion chamber 12, acting characteristics superheater? The use of flue gas heated to a certain pressure saturated steam superheated steam. 13, bag filter works and composition? Principle: inlet flue gas-containing flue dust particles into the lower caul plate over the flue dust reduction chamber, and then through the outlet to reduce the wind speed of the flue draft fan withdrawn via the discharge plenum chamber clean flue upper portion of the bag filter the atmospheric composition: inlet flue, the caul plate, the reduction of flue gas chamber, bag, net flue gas plenum chamber exit gas, ash silo, rotating ash blowing device, the air reservoir. 14, to the mounting position of the coal feeder, the number, composition mounted on the front wall of the furnace, the number of stage three consists of: a motor, a belt coal feeder, reducer, the motor slide. 15, the process of slag from the furnace down the three tap outlet derived by the discharge of slag, after water cooling to cool to a certain temperature onto the cooling belt-type transfusion Pa, and then transported by the inclined transport slag to the slag bin .