nutshell fired boilers price

Not on the bottom of the water (2) Gas nutshell fired boilers price ground surface to prevent moisture corrosion. 2, gas boiler run every 2-3 weeks, should be checked once. 3, gas boiler run every 3-6 months after the shutdown should conduct a comprehensive inspection.

Air scaling coefficient α (not on predetermined criteria)? A: According to GB / T16157-1996 "emissions from stationary sources of particulate matter and gaseous pollutants measured sampling methods", SO2 emission concentration of nutshell fired boilers price should be converted into the measured excess air coefficient α = 1.8 at a concentration of emission.

There are five main current production model, 50 kg, 100 kg, 300 kg, 500 kg and 1 ton steam nutshell fired boilers price. 1 ton steam boiler is now zui larger sizes, but for industrial boilers, a 1 ton considered small steam boiler.

Recently, the letters and the ecological environment unit, the letter of "nutshell fired boilers price air pollutant emission standards" in the "gas boiler exhaust pipe predetermined height of not less than 8 meters, within 200 meters from the building around the radius of the new boiler room chimney when was the tallest building in which the chimney should be higher than 3 meters "requirement questions.

First, the new urban gas boiler chimney should be performed outside the specified height is 3 meters above the surrounding buildings (there are many communities within 200 meters around the building height higher)?

Second, on the 20t / h steam boiler and above, and more than 14MW hot water boiler to be installed pollution-line monitoring equipment, this means that a single 14MW boiler or boiler means the total audience of 14MW?

Third, for example, I have more than 2MW heating station natural gas hot water boiler 7 units, exhaust gas through the two exhaust pipe emissions, the need to install pollution monitoring equipment?

A "boiler air pollutant emission standards" (GB13271-2014) states that "fuel, gas boiler stack height of not less than 8 m, particularly boiler stack height is determined by the EIA document approved. Chimney around the new boiler room when there is a building within a radius of 200 meters, the tallest building in which the chimney should be higher than 3 meters. when there is a building within 200 meters around the new boiler house chimney radius, "according to the provisions in the new urban area gas boiler should be implemented", the chimney should be higher than the provisions of the tallest buildings in more than 3 meters, "the.

Two, 20t / h steam boiler and above, 14MW and more hot water boiler must be installed in the line monitoring apparatus contaminants "14MW and more hot water boiler" means a single boiler.

Third, on the "exhaust gas through the two exhaust pipe emissions, the need to install pollution monitoring equipment" problem, according to "People's Republic of China Air Pollution Prevention Law" Article 24 "key sewage units should be installed, using air pollutant emissions automatic monitoring equipment, and environmental protection departments to monitor network devices, monitoring equipment to ensure the normal operation of public and emissions information in accordance with law. "provisions, as well as the" State Council on the issuance of three-year action plan to win the blue sky to defend the notice "(Guo Fa [2018 ] No. 22) "outfall height of over 45 meters of elevated source, as well as petrochemicals, chemicals, packaging, printing, painting and other VOCs emissions from industrial sources focus, the focus of sewage into the Directory of key areas should be basically completed by the end of 2019 to install flue gas automatic monitoring facilities, the country should be basically completed by the end of 2020 the automatic installation of flue gas monitoring facilities. "requirements, if the exhaust pipe where the company was listed as key units of sewage, flue gas monitoring facilities should be installed automatically, otherwise, no installation.