waste heat recovery boiler auxiliaries

2, ensure that the waste heat recovery boiler auxiliaries water, electricity, gas;

3, looking for experienced, competent fireman.

Some users of the hot water waste heat recovery boiler auxiliaries in the course due to man-made or other factors make the furnace wall is damaged, our performance from damage, damage causes, and made three summary, I hope you can help solve this problem in a timely manner.

December 1, fast Boiler Co., Ltd. received customers from Ukraine, headquarters staff warmly received the guests from afar, and send a professional team of foreign trade and technical engineers accompany the customer to the company headquarters R & D centers, laboratories, manufacturing plant and cloud services platform to showcase and explain.

6 tons of gas steam waste heat recovery boiler auxiliaries start / ignition / boost a description, unit 1 starts, the boiler starts to open the first draft fan. 2, the induced draft fan starts normally from about 1 to 3 minutes blower opening. 3, starting Cleaner. 4, rotation of the grate, and adjusted appropriately stalls second ignition 1, ignition starts after all the examination was normal, the amount of wind and the wind blowing good after normal combustion seam to be adjusted to maintain a certain furnace pressure (-15 ~ -30Pa ). 2, when the temperature is increased Stokes is not too fast, the time from ignition to supply the steam required for less than 2 hours. 3, when the air vent has steam coming off when air vent. Third, the booster 1, when the boiler is boosted to 0.1 ~ 0.2MPa, to the flushing water pressure gauges trap. 2, when the boiler is boosted to 0.2 ~ 0.3MPa, to check every one hole, hand holes, valves and other leaks, if the screws are loose (if the screws are loose, the screw must be tightened). 3 when the boiler is pressurized to 0.3 to 0.4MPa, sewage drain valve open time of the drum, reducing the temperature difference between the upper and lower drum to promote water circulation. 4, when the drum steam pressure gradually increased, the components of the boiler to be noted that there are no special or abnormal sound occurs, if the above anomalies, should immediately check, shutdown can check, if necessary, until the fault is cleared before continuing 6 run. 5, during boiler Stokes, economizer outlet water temperature must be monitored to prevent moisture inside of the economizer, economizer valve leading to the drum can be closed if necessary, open the economizer recirculation valve leading to the tank, of water economizer alone, but before the steam supply to return to normal position, to prevent water shortages.